News & Updates
RSSMSP Sponsers Speaker at Seven Springs RT Conference
MSP is spending today and tomorrow at the Seven Springs RC Conference in Champion, PA. MSP has sponsored guest speaker, Bob Tero, for the conference to talk about Pulsatile Flow Ventilation.
RSSMSP Welcomes New Customer Service Representative
MSP is proud to announce the latest addition to our Customer Service department, Angie. Angie joined our team in January and has had an impressive start here at MSP. Born and raised in Lititz, PA, Angie attended Warwick Schools. She … Continue reading
RSSRepresenting MSP at New Jersery Conference
Today we are at the St Barnabas conference in Garwood, NJ, focusing on transcutaneous monitoring, secretion management, and ventilation. We love connecting with our customers and finding ways we can better service their needs.
RSSHappy New Year
Medical Support Products’ main office will be closed New Year’s Day. We will have staff on-call ready to help with your rental needs. Please call 1-800-226-3783 to start a rental anytime. From all of us here at MSP, Happy New … Continue reading
RSSMerry Christmas from all of us at MSP
The Medical Support Products office will be closing at 4PM EST on Christmas Eve.
RSSHOLIDAY SHIPPING DELAYS
Due to holiday closings with many of our vendors, please allot extra time for your order to be delivered. We strive for excellent customer service and will do our best to ship each order as quickly as possible. Merry Christmas … Continue reading
RSSMSP Closed for Thanksgiving
Happy Thanksgiving to you and yours from all of us here at Medical Support Products. We will be closed for the holiday, but will have rental drivers on-call for your emergent rental needs. If you need emergent rental assistance, please … Continue reading
RSSNew Location Before and After Photos
Hi everyone! We have been in our new location for just over a month now and we are settling in nicely. We are loving the new building and we feel this new space will help us provide even better service … Continue reading
RSSWant to be a part of the MSP team? We are currently seeking a part-time Customer Service Representative!
At Medical Support Products our Customer Service Representatives serve as the first impression to our valued customers. This part-time role will deal directly with our customers, using problem-solving skills, to professionally assist them with their various needs. Representatives also serve … Continue reading
RSSHAPPY RESPIRATORY CARE WEEK
We’re wishing all respiratory care providers out there a wonderful Respiratory Care Week!! Thank you for all you do!
Follow Us

Maxtec MAX-13 Replacement Oxygen Sensor - R115P10

Maxtec MAX-13 Replacement Oxygen Sensor - R115P10
Brand: Maxtec Inc.
Product Code: R115P10
Availability: In Stock
Price: $79.00
Qty      - OR -    Add to Wish List
Compare this Product

The Maxtec MAX-13 Replacement Oxygen Sensor is the top choice for replacing the sensor in compatible oxygen analysis devices. With a response time of 13 seconds, a 3% linearity, and a 9.0-17.0 V output, this sensor is designed to meet the requirements and be compatible with the following equipment and brands [with part names and/or numbers]:

  • Airshields [See Hillrom]
  • Analytical Industries [PSR-11-917-J]
  • BCI [R-17]
  • Bio-Med Devices [10006 Sensor, M-10, M-2 Monitors, Sensor #4433, Monochrome Crossvent (use Max-13c)]
  • Biotest [C102-1]
  • City Technoligies [MOX-2] *Not compatible withthe following models Mindray A5, A4, A3 (Use the MAX-15LF for these models)
  • Covidien (Puritan-Bennett) [4-020933-00, PB850, 7820 Monitor, 7200 Vent]
  • Datascope [Anestar S]
  • EnviteC [OOM-102-1]
  • Hillrom (Airshields) [6735142]
  • GE (Datex-Ohmeda) [6051-0000-217, Erica, Elvira]
  • Hamilton [HM-11]
  • Hillrom [6735142]
  • Hudson RCI [See Teleflex Medical]
  • Invivo [9445 Sensor]
  • Integral Process [65005]
  • Kontron [ABT 5100]
  • Lifecare [R115P10]
  • Mercury Medical [10-103-05]
  • MSA [406931, MiniOX I, II, III, 3000]
  • Oxitron [3310]
  • Pacifitech [PT-11A]
  • Phillips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor]
  • Precision Medical [PM5900, #504877]
  • Puritan-Bennett [See Covidien]
  • Sensidyne (Maxtec) [V-11AV]
  • Sensor Tech [ST-11]
  • Taema [Eoie]
  • Teledyne [R17MED, #C-43690 (see Max-7 for AX/MX300 replacement]
  • Teleflex Medical (Hudson RCI) [5567, V-11]
  • Viasys [66030 Sensor, 6400 Ventilator, 8400 Ventilator, VIP Ventilator]
  • Ventrex [V-11A]
  • VTI [100580]

Specs:

Output: 9.0 to 17.0 mV
Response Time: ≤ 13 seconds
Linearity: < 3% error